Products

Microprocessor controlled Centrifuge “Macrotronic-BLT” and “Macrofriger-BLT”


Product Description


Induction drive maintenance free motor.
Low noise level 50-60dBa.
Robust all metal construction:

External case made from DUR-Al alloy.
Internal bowl and top plate all stainless steel
Internal steel safety chamber within the case.

Electronic circuits, microprocessor digital control of all parameters and functions:
speed, acceleration, brake, RCF, temperature, timer, 10 program storage, automatic rotor recognition and alarm system.

Rotor identification head, when the centrifuge lid is closed the rotor communicates all the data of the functions of it. This prevents, before use, any risk of failure of using the wrong rotor in a program or exceeding the rotors running parameters. The advantage of this system is that we can add additional rotors to the range without changing the centrifuge model.
All Rotors, buckets and adapters are identified with an inalterable engraved laser code.
Air circulation system, for centrifuges without refrigeration to limit any excessive rise in temperature within the centrifuge, all air circulated within the chamber is channelled out of the back and is not re-circulated, this means that the centrifuges internal temperature will remain low and constant.
Hermetically sealed compressor, mounted on anti-vibration mounts with re-circulating evaporator around the centrifuge chamber. (only applies to refrigerated centrifuges).


Technical Specifications


Multi-capability. Capacity from 1.5/2.2 ml vials up to tubes of 500 ml and 500 ml blood bags. Maintenance free induction motor drive.
CONTROL PANEL

TFT Touch screen
1. Stop process key.                                                                        8. Door opening key.
2. Start process key.                                                                        9. RPM or RCF real-time reading.
3. Increase value key.                                                                     10. Sequential operation.
4. Decrease value key.                                                                    11. Time set-up in process.
5. Scheduled acceleration ramp.                                                       12. Key to change RPM / RCF.
6. Rotor model in use.                                                                     13. Braking ramp programmed.
7. Reading the real time temperature.(refrigerated models only).        14. Return key.


Full Details